we are your liver experts & it’s time to see liver health in a new way
Introducing the Mindray Hepatus Platform. Experience an ultrasound device dedicated to hepatology. A system that enables you to scan confidently, diagnose efficiently, and see liver disease in real-time. The Hepatus is NexGen transient elastography that measures the attenuation and elasticity. Plus it provides the exact location of the sample in a single non-invasive exam.
INVESTING IN YOUR PATIENTS. INVESTING IN YOUR PRACTICE. SCAN CONFIDENTLY. DIAGNOSE EFFICIENTLY.
HEPATUS—NEXTGEN TRANSIENT ELASTOGRAPHY
SPEED IS AN IMPORTANT TOOL IN DISEASE MANAGEMENT
WHAT IS HEPATUS
Mindray’s latest technology in liver care is a complete solution for non-invasive testing (NIT) for liver disease management utilizing NexGen transient elastography technology.
NexGen TRANSIENT ELASTOGRAPHY W/ AUTOMATED TOOLS
Complete solutions for non-invasive live disease management using transient elastography.
AUTOMATED TOOLS
- Liver Stiffness Quantitative Analysis (fibrosis)
- Liver Ultra-sound Attenuation (fatty liver)
- Automatic measurement tool (Q-scan)
- Quality Control Index
TRANSDUCERS
- ViTE Transducer
- Curved Transducer (c5-1s)*
DESIGN
- 15” screen
- 2 hours of battery life
Liver Stiffness Quantitative Analysis
Quantitative evaluation of liver stiffness and fibrosis by transient elastography
LiSA: Liver Ultra-sound Attenuation
Quantitative evaluation of liver steatosis based on ultrasonic attenuation.
AUTOMATIC Q-SCAN MEASUREMENTS
PERFORMING Q-SCAN INTELLIGENT ACQUISITION
- System activates acquisition automatically until 10 valid values are obtained or the system activates acquisition 15 times by a single press of one button
- Precise and valid detection results can be obtained immediately within merely 7 seconds after positioning
- Automatically deletes invalid results
- This shortens the detection time and improves efficiency
QUALITY CONTROL INDEX
- (P)- Probe pressure index, ensuring appropriate pressure
- (M-STB)- Respiratory movement disturbance indicator & proper probe pressure
- Clear indication with different colors to improve quality control during the examination
Respiratory movement disturbance
Probe pressure too low
Respiratory movement disturbance
Probe pressure too low
Respiratory movement disturbance
Probe pressure too low
SMART TREND ANALYSIS SOFTWARE
Review historical exams and export data for research & analysis:
INTELLIGENT TREND ANALYSIS
- Follow up the exam results at later times and conduct trend analysis
- Convenient for doctors to monitor the changes in liver status and conducive to disease tracking and treatment evaluation.
- Detection data can be exported in batches for research and analysis